• Home
  • Browse
    • Current Issue
    • By Issue
    • By Author
    • By Subject
    • Author Index
    • Keyword Index
  • Journal Info
    • About Journal
    • Aims and Scope
    • Editorial Board
    • Publication Ethics
    • Peer Review Process
  • Guide for Authors
  • Submit Manuscript
  • Contact Us
 
  • Login
  • Register
Home Articles List Article Information
  • Save Records
  • |
  • Printable Version
  • |
  • Recommend
  • |
  • How to cite Export to
    RIS EndNote BibTeX APA MLA Harvard Vancouver
  • |
  • Share Share
    CiteULike Mendeley Facebook Google LinkedIn Twitter
Alexandria Dental Journal
arrow Articles in Press
arrow Current Issue
Journal Archive
Volume Volume 50 (2025)
Volume Volume 49 (2024)
Volume Volume 48 (2023)
Volume Volume 47 (2022)
Volume Volume 46 (2021)
Issue Issue 3
A (Oral and maxillofacial surgery, oral medicine, periodontology, oral radiology, oral pathology, oral biology)
Issue Issue 3
B (Endodontics, Prosthodontics, Fixed prosthodontics, Conservative dentistry, Dental Biomaterials)
Issue Issue 3
C (Pediatric dentistry, Dental public health, Orthodontics)
Issue Issue 2
A (Oral and maxillofacial surgery, oral medicine, periodontology, oral radiology, oral pathology, oral biology)
Issue Issue 2
B (Endodontics, Prosthodontics, Fixed prosthodontics, Conservative dentistry, Dental Biomaterials)
Issue Issue 2
C (Pediatric dentistry, Dental public health, Orthodontics)
Issue Issue 1
A (Oral and maxillofacial surgery, oral medicine, periodontology, oral radiology, oral pathology, oral biology)
Issue Issue 1
B (Endodontics, Prosthodontics, Fixed prosthodontics, Conservative dentistry, Dental Biomaterials)
Issue Issue 1
C (Pediatric dentistry, Dental public health, Orthodontics)
Volume Volume 45 (2020)
Volume Volume 44 (2019)
Volume Volume 43 (2018)
Volume Volume 42 (2017)
Volume Volume 41 (2016)
Volume Volume 40 (2015)
Akmal, A., Shalaby, Y., Azer, A. (2021). THE IMPACT OF A HIGH MAGNIFICATION APPROACH FOR TEETH PREPARATIONS ON THE MARGINAL FIT OF CAD/CAM MONOLITHIC LITHIUM DISILICATE CROWNS (IN VITRO STUDY). Alexandria Dental Journal, 46(Issue 1), 106-110. doi: 10.21608/adjalexu.2020.22538.1038
Alaa Akmal; Yousria Shalaby; Amir Azer. "THE IMPACT OF A HIGH MAGNIFICATION APPROACH FOR TEETH PREPARATIONS ON THE MARGINAL FIT OF CAD/CAM MONOLITHIC LITHIUM DISILICATE CROWNS (IN VITRO STUDY)". Alexandria Dental Journal, 46, Issue 1, 2021, 106-110. doi: 10.21608/adjalexu.2020.22538.1038
Akmal, A., Shalaby, Y., Azer, A. (2021). 'THE IMPACT OF A HIGH MAGNIFICATION APPROACH FOR TEETH PREPARATIONS ON THE MARGINAL FIT OF CAD/CAM MONOLITHIC LITHIUM DISILICATE CROWNS (IN VITRO STUDY)', Alexandria Dental Journal, 46(Issue 1), pp. 106-110. doi: 10.21608/adjalexu.2020.22538.1038
Akmal, A., Shalaby, Y., Azer, A. THE IMPACT OF A HIGH MAGNIFICATION APPROACH FOR TEETH PREPARATIONS ON THE MARGINAL FIT OF CAD/CAM MONOLITHIC LITHIUM DISILICATE CROWNS (IN VITRO STUDY). Alexandria Dental Journal, 2021; 46(Issue 1): 106-110. doi: 10.21608/adjalexu.2020.22538.1038

THE IMPACT OF A HIGH MAGNIFICATION APPROACH FOR TEETH PREPARATIONS ON THE MARGINAL FIT OF CAD/CAM MONOLITHIC LITHIUM DISILICATE CROWNS (IN VITRO STUDY)

Article 6, Volume 46, Issue 1, April 2021, Page 106-110  XML PDF (263.68 K)
Document Type: Original Article
DOI: 10.21608/adjalexu.2020.22538.1038
View on SCiNiTO View on SCiNiTO
Authors
Alaa Akmal email 1; Yousria Shalaby2; Amir Azerorcid 3
1Conservative Dentistry Department, Faculty of Dentistry, Alexandria University
2Department of Conservative Dentistry, Faculty of Dentistry, Alexandria University.
3Lecturer, Department of Conservative Dentistry, Faculty of Dentistry, Alexandria University.
Abstract
Introduction: Marginal integrity is a challenging goal revealing an accurate restoration with definite marginal adaptation thus inflammation of gingival tissues and bone destruction correlate directly with a poor marginal property of the restoration. These days improved vision is essential in dentistry upgrading exactness and flawlessness.
Objectives: To assess the impact of amplification on the marginal adaptation of CAD/CAM monolithic lithium disilicate crowns.
Materials and Methods: In-vitro study using 16 upper right cuspid typodont teeth; divided into two entities according to tooth preparation approach (n=8). Group I teeth preparation without magnification (control group), Group II teeth preparation utilizing the dental operating microscope (DOM) under magnification of 16x. Optical impressions were taken through scanning by Sirona inEOS X5 extra-oral scanner where full anatomical crowns were structured, processed, Sintered and glazed. CBCT was utilized to quantify the minimal gapes before and after cementation/aging.
Results: Marginal gaps were significantly increased after cementation and aging in both groups yet still inside the worthy minimal gap values. Group II demonstrated recognizable less marginal gaps.
Conclusions: Operating microscopy OM is a significant supplement to the armamentarium of present-day dentistry. It helps set the bar of greatness and flawlessness at the most elevated level including every dental field.
Keywords
Microscope; Fit; Cone beam; Monolithic; Lithium Disilicate
Main Subjects
Fixed prosthodontics
References
Oilo M, Gjerdet NR, Tvinnereim HM. The firing procedure influences properties of a zirconia core ceramic. Dent Mater. 2008;24:471-5.

  • Zarone F, Ferrari M, Mangano FG, Leone R, Sorrentino R. "Digitally Oriented Materials": Focus on Lithium Disilicate Ceramics. Int J Dent.2016:9840594.

  • Fabbri G, Zarone F, Dellificorelli G, Cannistraro G, De Lorenzi M, Mosca A, et al. Clinical evaluation of 860 anterior and posterior lithium disilicate restorations: retrospective study with a mean follow-up of 3 years and a maximum observational period of 6 years. Int J Periodontics Restorative Dent. 2014;34:165-77.

  • Conrad HJ, Seong WJ, Pesun IJ. Current ceramic materials and systems with clinical recommendations: a systematic review. J Prosthet Dent. 2007;98:389-404.

  • Karlsson S. The fit of Procera titanium crowns. An in vitro and clinical study. Acta Odontol Scand. 1993;51:129-34.

  • May KB, Russell MM, Razzoog ME, Lang BR. Precision of fit: the Procera AllCeram crown. J Prosthet Dent. 1998;80:394-404.

  • Alfaro DP, Ruse ND, Carvalho RM, Wyatt CC. Assessment of the Internal Fit of Lithium Disilicate Crowns Using Micro-CT. J Prosthodont. 2015;24(5):381-6.

  • Schaefer O, Decker M, Wittstock F, Kuepper H, Guentsch A. Impact of digital impression techniques on the adaption of ceramic partial crowns in vitro. J Dent. 2014;42:677-83.

  • Carr GB, Murgel CAF. The use of the operating microscope in endodontics. Dent Clin North Am. 2010;54:191- 214.

  • Beschnidt SM, Strub JR. Evaluation of the marginal accuracy of different all-ceramic crown systems after simulation in the artificial mouth. J Oral Rehabil.1999;26:582-93.

  • Darwish HA, Salah TS, Dimeery AG. Internal fit of lithium disilicate and resin nano-ceramic endocrowns with different preparation designs. FDJ. 2017;1: 67-72.

  • Low JF, Mohd Dom TN, Baharin SA. Magnification in endodontics: A review of its application and acceptance among dental practitioners. Eur J Dent. 2018;12:610-6.

  • Ram HK, Shah RJ, Agrawal HS. Evaluation of three different tooth preparation techniques for metal ceramic crowns by comparing preparation depths: An in vitro study. J Indian Prosthodont Soc. 2015;1:162-7.

  • Gehrt M, Wolfart S, Rafai N, Reich S, Edelhoff D. Clinical results of lithium-disilicate crowns after up to 9 years of service. Clin Oral Invest 2013;17:275-84.

  • Komet USA - Burs & Rotary Instruments for Dental Surgery. Available at: https://www.kometusa.com/V2/us/Products/Dental-Surgery/Category/Diamond/Pin-Diamonds/856P.aspx

  • Elmagd AAAA, Abdel Bary SK. Evaluation of marginal gap of zirconium crown after aging cycle of thermoplastic resin clasp. In 2015.

  • BISCO Dental Documents | BISCO Dental [Internet]. [cited 2020 Feb 9]. Available from: https://www.bisco.com/documents/?CategoryId=1

  • Kelly JR, Rungruanganunt P, Hunter B, Vailati F. Development of a clinically validated bulk failure test for ceramic crowns. J Prosthet Dent. 2010;104:228-38.

  • Orsi IA, Varoli FK, Pieroni CHP, Ferreira MCCG, Borie E. In vitro tensile strength of luting cements on metallic substrate. Braz Dent J. 2014;25:136-40.

  • Elguindy JF, Mostafa DH, Agroudi MA. Margin assessment and fracture resistance of adhesively luted ceramic crowns. J Am Sci. 2010;6:264-73.

  • Kern M, Sasse M, Wolfart S. Ten-year outcome of three-unit fixed dental prostheses made from monolithic lithium disilicate ceramic. J Am Dent Assoc. 2012;143:234-40.

  • Raptis NV, Michalakis KX, Hirayama H. Optical behavior of current ceramic systems. Int J Periodontics Restorative Dent. 2006;26:31-41.

  • Pavan S, dos Santos PH, Berger S, Bedran-Russo AKB. The effect of dentin pretreatment on the microtensile bond strength of self-adhesive resin cements. J Prosthet Dent. 2010;104:258-64.

  • McLean JW, von Fraunhofer JA. The estimation of cement film thickness by an in vivo technique. Br Dent J. 1971;131:107-11.

  • Bindl A, Mörmann WH. Marginal and internal fit of all-ceramic CAD/CAM crown-copings on chamfer preparations. J Oral Rehabil. 2005;32:441-7.

  • Henkel GL. A comparison of fixed prostheses generated from conventional vs digitally scanned dental impressions. Compend Contin Educ Dent.2007;28:422-4, 426-8, 430-1.

  • Holmes JR, Sulik WD, Holland GA, Bayne SC. Marginal fit of castable ceramic crowns. J Prosthet Dent. 1992;67:594-9.

    Kumar M, Shanavas M, Sidappa A, Kiran M. Cone beam computed tomography - Know its secrets. J Int Oral Health 2015;7:64-8.

  • Alkumru H, Hullah WR, Marquis PM, Wilson HJ. Factors affecting the fit of porcelain jacket crowns. Br Dent J. 1988;164:39-43.

  • Lien W, Roberts HW, Platt JA, Vandewalle KS, Hill TJ, Chu T-MG. Microstructural evolution and physical behavior of a lithium disilicate glass-ceramic. Dent Mater. 2015;31:928-40.

  • Aboudorra HA, Amr H, Hafez A, Hassan AA. Internal fit evaluation of all ceramic restoration fabricated by two CAD/CAM milling systems using cone beam CT (CBCT). 65:13.

  • Selden HS. The role of a dental operating microscope in improved nonsurgical treatment of ‘calcified’ canals. Oral Surg Oral Med Oral Pathol. 1989;68:93-8.

    Statistics
    Article View: 313
    PDF Download: 584
    Home | Glossary | News | Aims and Scope | Sitemap
    Top Top

    Journal Management System. Designed by NotionWave.