• Home
  • Browse
    • Current Issue
    • By Issue
    • By Author
    • By Subject
    • Author Index
    • Keyword Index
  • Journal Info
    • About Journal
    • Aims and Scope
    • Editorial Board
    • Publication Ethics
    • Peer Review Process
  • Guide for Authors
  • Submit Manuscript
  • Contact Us
 
  • Login
  • Register
Home Articles List Article Information
  • Save Records
  • |
  • Printable Version
  • |
  • Recommend
  • |
  • How to cite Export to
    RIS EndNote BibTeX APA MLA Harvard Vancouver
  • |
  • Share Share
    CiteULike Mendeley Facebook Google LinkedIn Twitter
Alexandria Dental Journal
arrow Articles in Press
arrow Current Issue
Journal Archive
Volume Volume 50 (2025)
Volume Volume 49 (2024)
Volume Volume 48 (2023)
Issue Issue 3
A (Oral and maxillofacial surgery, oral medicine, periodontology, oral radiology, oral pathology, oral biology)
Issue Issue 3
B (Endodontics, Prosthodontics, Fixed prosthodontics, Conservative dentistry, Dental Biomaterials)
Issue Issue 3
C (Pediatric dentistry, Dental public health, Orthodontics)
Issue Issue 2
A (Oral and maxillofacial surgery, oral medicine, periodontology, oral radiology, oral pathology, oral biology)
Issue Issue 2
B (Endodontics, Prosthodontics, Fixed prosthodontics, Conservative dentistry, Dental Biomaterials)
Issue Issue 2
C (Pediatric dentistry, Dental public health, Orthodontics)
Issue Issue 1
A (Oral and maxillofacial surgery, oral medicine, periodontology, oral radiology, oral pathology, oral biology)
Issue Issue 1
B (Endodontics, Prosthodontics, Fixed prosthodontics, Conservative dentistry, Dental Biomaterials)
Issue Issue 1
C (Pediatric dentistry, Dental public health, Orthodontics)
Volume Volume 47 (2022)
Volume Volume 46 (2021)
Volume Volume 45 (2020)
Volume Volume 44 (2019)
Volume Volume 43 (2018)
Volume Volume 42 (2017)
Volume Volume 41 (2016)
Volume Volume 40 (2015)
Alganabi, Z., Nawar, E., Saad, M. (2023). STRAIN ASSESSMENT OF COBALT CHROMIUM VERSUS POLY-ETHER-ETHER-KETONE FOR REINFORCING MANDIBULAR OVERDENTURE ASSISTED BY TWO IMPLANTS (A COMPARATIVE IN-VITRO STUDY). Alexandria Dental Journal, 48(3), 143-151. doi: 10.21608/adjalexu.2022.150941.1299
Zaid Alganabi; Elsayed Abdul khader Nawar; Mona Sabry Saad. "STRAIN ASSESSMENT OF COBALT CHROMIUM VERSUS POLY-ETHER-ETHER-KETONE FOR REINFORCING MANDIBULAR OVERDENTURE ASSISTED BY TWO IMPLANTS (A COMPARATIVE IN-VITRO STUDY)". Alexandria Dental Journal, 48, 3, 2023, 143-151. doi: 10.21608/adjalexu.2022.150941.1299
Alganabi, Z., Nawar, E., Saad, M. (2023). 'STRAIN ASSESSMENT OF COBALT CHROMIUM VERSUS POLY-ETHER-ETHER-KETONE FOR REINFORCING MANDIBULAR OVERDENTURE ASSISTED BY TWO IMPLANTS (A COMPARATIVE IN-VITRO STUDY)', Alexandria Dental Journal, 48(3), pp. 143-151. doi: 10.21608/adjalexu.2022.150941.1299
Alganabi, Z., Nawar, E., Saad, M. STRAIN ASSESSMENT OF COBALT CHROMIUM VERSUS POLY-ETHER-ETHER-KETONE FOR REINFORCING MANDIBULAR OVERDENTURE ASSISTED BY TWO IMPLANTS (A COMPARATIVE IN-VITRO STUDY). Alexandria Dental Journal, 2023; 48(3): 143-151. doi: 10.21608/adjalexu.2022.150941.1299

STRAIN ASSESSMENT OF COBALT CHROMIUM VERSUS POLY-ETHER-ETHER-KETONE FOR REINFORCING MANDIBULAR OVERDENTURE ASSISTED BY TWO IMPLANTS (A COMPARATIVE IN-VITRO STUDY)

Article 5, Volume 48, Issue 3, December 2023, Page 143-151  XML PDF (597.97 K)
Document Type: Original Article
DOI: 10.21608/adjalexu.2022.150941.1299
View on SCiNiTO View on SCiNiTO
Authors
Zaid Alganabi email 1; Elsayed Abdul khader Nawar2; Mona Sabry Saadorcid 1
1Department of Prosthodontics, Faculty of Dentistry, Alexandria University, Egypt
2Prosthodontics, Department of Prosthodontics, Faculty of Dentistry, Alexandria University, Egypt
Abstract
Introduction: Patients with a traditional denture may have difficulty chewing because of the absence of retention. Recently, using two un-splinted implants assisted overdenture to overcome the retention problem. But still Acrylic material has problems; such as lowers impact, fatigue strengths, and fracture. Reinforcement of acrylic denture base to avoid fracture by a variety of materials such as; Metal reinforcement, fillers like carbon fiber, and Poly-Ether-Ether-Ketone (PEEK) is frequently utilized in dentistry and is seen as a viable alternative to traditional materials.
Aim of the study: Compare between Two different denture base reinforcement materials (CoCr) and (PEEK) in comparison to acrylic dentures on strain around two implant-assisted mandibular overdenture and on ridge area.
Materials and methods: 3 epoxy models were used with two implants placed at the canine region. 8 mandibular overdenture were constructed for each group; (group A) Acrylic overdenture without reinforcement, for (group B) and (group c) acrylic overdenture were reinforcement by (CoCr, PEEK) respectively. Six linear strain gauges were used at the mesial and distal of each implant, and under the lower second molars bilaterally. Strain measurements were taken under central and unilateral loading around the two implants and on the ridge regions.
Results: No significant difference between all groups upon application of central load 100N on ridges. However, group C showed lower strain values upon application of central and unilateral loading 100N.
Conclusion: PEEK reinforcement material showed less strain values with favorable stress distribution when compared to Acrylic and cobalt chromium reinforcement material for implant-assisted mandibular overdenture.
Keywords
Denture base reinforcement; Cobalt-Chromium alloy; PEEK; Implant assisted overdenture; ball and socket attachment
Main Subjects
Prosthodontics
Statistics
Article View: 193
PDF Download: 339