• Home
  • Browse
    • Current Issue
    • By Issue
    • By Author
    • By Subject
    • Author Index
    • Keyword Index
  • Journal Info
    • About Journal
    • Aims and Scope
    • Editorial Board
    • Publication Ethics
    • Peer Review Process
  • Guide for Authors
  • Submit Manuscript
  • Contact Us
 
  • Login
  • Register
Home Articles List Article Information
  • Save Records
  • |
  • Printable Version
  • |
  • Recommend
  • |
  • How to cite Export to
    RIS EndNote BibTeX APA MLA Harvard Vancouver
  • |
  • Share Share
    CiteULike Mendeley Facebook Google LinkedIn Twitter
Alexandria Dental Journal
arrow Articles in Press
arrow Current Issue
Journal Archive
Volume Volume 50 (2025)
Volume Volume 49 (2024)
Issue Issue 3
A (Oral and maxillofacial surgery, oral medicine, periodontology, oral radiology, oral pathology, oral biology)
Issue Issue 3
B (Endodontics, Prosthodontics, Fixed prosthodontics, Conservative dentistry, Dental Biomaterials)
Issue Issue 3
C (Pediatric dentistry, Dental public health, Orthodontics)
Issue Issue 2
A (Oral and maxillofacial surgery, oral medicine, periodontology, oral radiology, oral pathology, oral biology)
Issue Issue 2
B (Endodontics, Prosthodontics, Fixed prosthodontics, Conservative dentistry, Dental Biomaterials)
Issue Issue 2
C (Pediatric dentistry, Dental public health, Orthodontics)
Issue Issue 1
A (Oral and maxillofacial surgery, oral medicine, periodontology, oral radiology, oral pathology, oral biology)
Issue Issue 1
B (Endodontics, Prosthodontics, Fixed prosthodontics, Conservative dentistry, Dental Biomaterials)
Issue Issue 1
C (Pediatric dentistry, Dental public health, Orthodontics)
Volume Volume 48 (2023)
Volume Volume 47 (2022)
Volume Volume 46 (2021)
Volume Volume 45 (2020)
Volume Volume 44 (2019)
Volume Volume 43 (2018)
Volume Volume 42 (2017)
Volume Volume 41 (2016)
Volume Volume 40 (2015)
Shehata, M., Alashwah, A., Ahmed, R., Ahmed, A. (2024). EVALUATION OF IMMEDIATE LOADED IMPLANTS PLACED USING THE SOCKET SHIELD TECHNIQUE IN THE ESTHETIC ZONE (A RANDOMIZED CONTROLLED CLINICAL TRIAL). Alexandria Dental Journal, 49(2), 66-72. doi: 10.21608/adjalexu.2023.192795.1351
Mohamed Mohamed Shehata; Adham Ahmed Alashwah; Rania A Ahmed; Ahmed Osama Ahmed. "EVALUATION OF IMMEDIATE LOADED IMPLANTS PLACED USING THE SOCKET SHIELD TECHNIQUE IN THE ESTHETIC ZONE (A RANDOMIZED CONTROLLED CLINICAL TRIAL)". Alexandria Dental Journal, 49, 2, 2024, 66-72. doi: 10.21608/adjalexu.2023.192795.1351
Shehata, M., Alashwah, A., Ahmed, R., Ahmed, A. (2024). 'EVALUATION OF IMMEDIATE LOADED IMPLANTS PLACED USING THE SOCKET SHIELD TECHNIQUE IN THE ESTHETIC ZONE (A RANDOMIZED CONTROLLED CLINICAL TRIAL)', Alexandria Dental Journal, 49(2), pp. 66-72. doi: 10.21608/adjalexu.2023.192795.1351
Shehata, M., Alashwah, A., Ahmed, R., Ahmed, A. EVALUATION OF IMMEDIATE LOADED IMPLANTS PLACED USING THE SOCKET SHIELD TECHNIQUE IN THE ESTHETIC ZONE (A RANDOMIZED CONTROLLED CLINICAL TRIAL). Alexandria Dental Journal, 2024; 49(2): 66-72. doi: 10.21608/adjalexu.2023.192795.1351

EVALUATION OF IMMEDIATE LOADED IMPLANTS PLACED USING THE SOCKET SHIELD TECHNIQUE IN THE ESTHETIC ZONE (A RANDOMIZED CONTROLLED CLINICAL TRIAL)

Article 9, Volume 49, Issue 2, August 2024, Page 66-72  XML PDF (513.7 K)
Document Type: Original Article
DOI: 10.21608/adjalexu.2023.192795.1351
View on SCiNiTO View on SCiNiTO
Authors
Mohamed Mohamed Shehata email 1; Adham Ahmed Alashwah2; Rania A Ahmedorcid 3; Ahmed Osama Ahmed4
1Oral and Maxillofacial Surgery, Faculty of Dentistry, Alexandria University
2Oral and Maxillofacial Surgery Department, Faculty of Dentistry, Alexandria University, Alexandria, Egypt
3Assistant Professor, Oral Medicine and Periodontology, Faculty of Dentistry, Alexandria University, Alexandria City, Egypt
4Oral and Maxillofacial Surgery Department, Faculty of Dentistry, Alexandria University, Egypt.
Abstract
Introduction: Once teeth are extracted, the alveolar bone with the labial bone plate reduction occurs as a consequence of the absence of blood flow. The socket-shield technique) SST) was introduced to end these consequences.
Objectives: Our goal was to compare between the conventional approach and the SST perspectives; clinical and radiographical.
Materials and Methods: 20 individuals were parted into 2 groups; the study group: The (SST) with immediate loading was applied 10 implants in the anterior maxilla. The control group: 10 implants were instantly placed using immediate implant placement (IIP) along with the immediate loading. For both groups, CBCT-scans were pre-operatively evaluated and 6 months period for evaluating the dimensional changes within the labial bone plates including both the vertical and horizontal bone loss (VBL, HBL), measuring of clinical attachment loss (CAL), the dental implant stability quotients (DISQs) and the pink esthetic scores (PES),
Results: The mean Dental Implant Stability (DISQ) was 77.92+2.44 and 75.14+2.34 in control and study groups respectively 6 months postoperatively, the average HBL bone level 6 months postoperative in Group 1 was 6.88+0.97mm, and in Group 2 was 6.74+0.93mm. While mean VBL level after 6 months of follow up in Groups 1 and 2 was 0.93+0.57mm, and 1.55+0.85mm respectively. The mean PES in Group 1 was 12.10+0.57 after 6 months, while in Group 2 was 7.80+1.14. The mean CAL 6 months Post-operatively in Group 1 and Group 2 was 0.90+0.57mm and 1.50+0.85mm respectively
Conclusions: The technique of socket-shield was conserved the labial root part
Keywords
Immediate implants; Extraction socket; immediate loading; socket shield technique
Main Subjects
Oral and maxillofacial surgery
Statistics
Article View: 963
PDF Download: 309
Home | Glossary | News | Aims and Scope | Sitemap
Top Top

Journal Management System. Designed by NotionWave.