• Home
  • Browse
    • Current Issue
    • By Issue
    • By Author
    • By Subject
    • Author Index
    • Keyword Index
  • Journal Info
    • About Journal
    • Aims and Scope
    • Editorial Board
    • Publication Ethics
    • Peer Review Process
  • Guide for Authors
  • Submit Manuscript
  • Contact Us
 
  • Login
  • Register
Home Articles List Article Information
  • Save Records
  • |
  • Printable Version
  • |
  • Recommend
  • |
  • How to cite Export to
    RIS EndNote BibTeX APA MLA Harvard Vancouver
  • |
  • Share Share
    CiteULike Mendeley Facebook Google LinkedIn Twitter
Alexandria Dental Journal
arrow Articles in Press
arrow Current Issue
Journal Archive
Volume Volume 50 (2025)
Issue Issue 2
A (Oral and maxillofacial surgery, oral medicine, periodontology, oral radiology, oral pathology, oral biology)
Issue Issue 2
B (Endodontics, Prosthodontics, Fixed prosthodontics, Conservative dentistry, Dental Biomaterials)
Issue Issue 2
C (Pediatric dentistry, Dental public health, Orthodontics)
Issue Issue 1
A (Oral and maxillofacial surgery, oral medicine, periodontology, oral radiology, oral pathology, oral biology)
Issue Issue 1
B (Endodontics, Prosthodontics, Fixed prosthodontics, Conservative dentistry, Dental Biomaterials)
Issue Issue 1
C (Pediatric dentistry, Dental public health, Orthodontics)
Volume Volume 49 (2024)
Volume Volume 48 (2023)
Volume Volume 47 (2022)
Volume Volume 46 (2021)
Volume Volume 45 (2020)
Volume Volume 44 (2019)
Volume Volume 43 (2018)
Volume Volume 42 (2017)
Volume Volume 41 (2016)
Volume Volume 40 (2015)
Aboseada, N., Mohamed, F., Elshabrawy, S. (2025). STRESS DISTRIPUTION OF IMPLANT RETAINED OBTURATORS USING TWO IMPLANT PLACEMENT CONFIGURATIONS FOR MAXILLECTOMY CASES: IN-VITRO STUDY. Alexandria Dental Journal, 50(1), 145-154. doi: 10.21608/adjalexu.2024.247196.1440
Nourhan Ibrahim Mahmoud Aboseada; Faten Salah Eldin Mohamed; Sonia Morsy Elshabrawy. "STRESS DISTRIPUTION OF IMPLANT RETAINED OBTURATORS USING TWO IMPLANT PLACEMENT CONFIGURATIONS FOR MAXILLECTOMY CASES: IN-VITRO STUDY". Alexandria Dental Journal, 50, 1, 2025, 145-154. doi: 10.21608/adjalexu.2024.247196.1440
Aboseada, N., Mohamed, F., Elshabrawy, S. (2025). 'STRESS DISTRIPUTION OF IMPLANT RETAINED OBTURATORS USING TWO IMPLANT PLACEMENT CONFIGURATIONS FOR MAXILLECTOMY CASES: IN-VITRO STUDY', Alexandria Dental Journal, 50(1), pp. 145-154. doi: 10.21608/adjalexu.2024.247196.1440
Aboseada, N., Mohamed, F., Elshabrawy, S. STRESS DISTRIPUTION OF IMPLANT RETAINED OBTURATORS USING TWO IMPLANT PLACEMENT CONFIGURATIONS FOR MAXILLECTOMY CASES: IN-VITRO STUDY. Alexandria Dental Journal, 2025; 50(1): 145-154. doi: 10.21608/adjalexu.2024.247196.1440

STRESS DISTRIPUTION OF IMPLANT RETAINED OBTURATORS USING TWO IMPLANT PLACEMENT CONFIGURATIONS FOR MAXILLECTOMY CASES: IN-VITRO STUDY

Article 28, Volume 50, Issue 1, April 2025, Page 145-154  XML PDF (445.39 K)
Document Type: Original Article
DOI: 10.21608/adjalexu.2024.247196.1440
View on SCiNiTO View on SCiNiTO
Authors
Nourhan Ibrahim Mahmoud Aboseada email 1; Faten Salah Eldin Mohamed2; Sonia Morsy Elshabrawy3
1prosthodontics department, Faculty of Dentistry, Alexandria University, Alexandria, Egypt
2Department of prosthodontics, faculty of dentistry. Alexandria University,Alexandria,Egypt
3Biomaterials department, Faculty of Dentistry, Alexandria University, Alexandria, Egypt
Abstract
ABSTRACT
Introduction: Implant-retained obturators have several advantages over traditional obturators for maxillectomy patients. Appropriate prosthetic design for specific condition after maxillary resection is essential for improvement of retention, stability of implant retained obturator.
Objectives: evaluation of peri-implant stress distribution of obturators retained by three implants placed with two different placement configurations.
Material and methods: Three implants arranged in linear configuration and other three implants arranged in nonlinear configuration were inserted into two identical epoxy resin maxillary models of completely edentulous unilateral maxillary defect (Brown’s class IIA). Two equal sets of twenty-six obturators were constructed; each with different implant placement configuration. Group I include thirteen obturators retained by three implants with linear configuration while Group II include thirteen obturators retained by three implants with nonlinear configuration. Both groups included the same attachment design (non-splinted Ball attachment). Using strain gauges, the two groups' differences in strain distribution were measured and compared. Using the universal testing machine, bilateral applications of vertical load and oblique load (30o and 45o) of 50 and 100 N were applied in order to assess stress distribution around implants.
Results: There was statistically significant difference in strain value between group I (linear configuration) and group II (nonlinear configuration) after application of 30o oblique loading at 50 N and 100 N with p value < 0.0001 as group II exhibited lower strain values.
Conclusions: Implant placed with nonlinear configuration showed less strain values than implant placed with linear configuration.
Keywords
Implant-retained obturator; Implant configuration; Ball and socket; Maxillectomy; strain gauges
Main Subjects
Prosthodontics
Statistics
Article View: 124
PDF Download: 179
Home | Glossary | News | Aims and Scope | Sitemap
Top Top

Journal Management System. Designed by NotionWave.