• Home
  • Browse
    • Current Issue
    • By Issue
    • By Author
    • By Subject
    • Author Index
    • Keyword Index
  • Journal Info
    • About Journal
    • Aims and Scope
    • Editorial Board
    • Publication Ethics
    • Peer Review Process
  • Guide for Authors
  • Submit Manuscript
  • Contact Us
 
  • Login
  • Register
Home Articles List Article Information
  • Save Records
  • |
  • Printable Version
  • |
  • Recommend
  • |
  • How to cite Export to
    RIS EndNote BibTeX APA MLA Harvard Vancouver
  • |
  • Share Share
    CiteULike Mendeley Facebook Google LinkedIn Twitter
Alexandria Dental Journal
arrow Articles in Press
arrow Current Issue
Journal Archive
Volume Volume 50 (2025)
Issue Issue 2
A (Oral and maxillofacial surgery, oral medicine, periodontology, oral radiology, oral pathology, oral biology)
Issue Issue 2
B (Endodontics, Prosthodontics, Fixed prosthodontics, Conservative dentistry, Dental Biomaterials)
Issue Issue 2
C (Pediatric dentistry, Dental public health, Orthodontics)
Issue Issue 1
A (Oral and maxillofacial surgery, oral medicine, periodontology, oral radiology, oral pathology, oral biology)
Issue Issue 1
B (Endodontics, Prosthodontics, Fixed prosthodontics, Conservative dentistry, Dental Biomaterials)
Issue Issue 1
C (Pediatric dentistry, Dental public health, Orthodontics)
Volume Volume 49 (2024)
Volume Volume 48 (2023)
Volume Volume 47 (2022)
Volume Volume 46 (2021)
Volume Volume 45 (2020)
Volume Volume 44 (2019)
Volume Volume 43 (2018)
Volume Volume 42 (2017)
Volume Volume 41 (2016)
Volume Volume 40 (2015)
Bassiony, M., Shalaby, Y., Azer, A., AboElhassan, R. (2025). THE INFLUENCE OF TWO STEAM STERILIZATION PARAMETERS ON THE DIMENSIONAL STABILITY OF 3D PRINTED SURGICAL GUIDE (IN VITRO STUDY). Alexandria Dental Journal, 50(2), 136-142. doi: 10.21608/adjalexu.2024.292052.1509
Mohamed Ahmed Bassiony; Yousria Attia Shalaby; Amir Shoukry Azer; Rewaa AboElhassan. "THE INFLUENCE OF TWO STEAM STERILIZATION PARAMETERS ON THE DIMENSIONAL STABILITY OF 3D PRINTED SURGICAL GUIDE (IN VITRO STUDY)". Alexandria Dental Journal, 50, 2, 2025, 136-142. doi: 10.21608/adjalexu.2024.292052.1509
Bassiony, M., Shalaby, Y., Azer, A., AboElhassan, R. (2025). 'THE INFLUENCE OF TWO STEAM STERILIZATION PARAMETERS ON THE DIMENSIONAL STABILITY OF 3D PRINTED SURGICAL GUIDE (IN VITRO STUDY)', Alexandria Dental Journal, 50(2), pp. 136-142. doi: 10.21608/adjalexu.2024.292052.1509
Bassiony, M., Shalaby, Y., Azer, A., AboElhassan, R. THE INFLUENCE OF TWO STEAM STERILIZATION PARAMETERS ON THE DIMENSIONAL STABILITY OF 3D PRINTED SURGICAL GUIDE (IN VITRO STUDY). Alexandria Dental Journal, 2025; 50(2): 136-142. doi: 10.21608/adjalexu.2024.292052.1509

THE INFLUENCE OF TWO STEAM STERILIZATION PARAMETERS ON THE DIMENSIONAL STABILITY OF 3D PRINTED SURGICAL GUIDE (IN VITRO STUDY)

Article 4, Volume 50, Issue 2, August 2025, Page 136-142  XML PDF (429.29 K)
Document Type: Original Article
DOI: 10.21608/adjalexu.2024.292052.1509
View on SCiNiTO View on SCiNiTO
Authors
Mohamed Ahmed Bassiony email 1; Yousria Attia Shalaby2; Amir Shoukry Azerorcid 3; Rewaa AboElhassanorcid 4
1Conservative Department, Faculty of Dentistry, Alexandria University, Alexandria, Egypt.
2Conservative Dentistry Department, Faculty of Dentistry, Alexandria University
3Conservative dentistry, Alexandria University, Alexandria, Egypt
4Conservative Department, Faculty of Dentistry, Alexandria University
Abstract
Background: Advanced manufacturing techniques, known as three-dimensional (3D) printing, use computer-aided digital design models to automatically produce customized three-dimensional objects.
Objective: The purpose of this study was to evaluate the effects of two different sterilizing methods on the dimensions of a 3D-printed surgical guide for implant treatment.
Methods: Based on the parameters of the sterilizing procedure, we conducted a controlled study with a prospective design on surgical guides, randomly dividing them into two groups of 13 specimens each. Group I underwent steam sterilization for 15 minutes at 121 °C, whereas Group II underwent sterilization for 10 minutes at 134 °C.
Results: Before autoclaving, Group I and Group II did not differ statistically significantly in area or perimeter (p = 0.128, p = 718). The percent change in area between the research groups compared pairwise showed a significant difference (p < 0.0001) between each group pair. The percentage changes in the area and perimeter between Group I and Group II were found to differ considerably (p < 0.0001).
Conclusions: The results of this investigation unequivocally show that steam sterilization procedures have a substantial impact on the stability and dimensional correctness of 3D-printed surgical guides. carefully choose settings to reduce distortion, even though sterilizing is essential. At 121°C for 15 minutes, steam sterilization appears to provide the best blend of microbiological inactivation and guide integrity preservation. Compression and shrinking are still possibilities.
Keywords
Steam Sterilization; Dimensional Stability; 3d Printed; Surgical Guide
Main Subjects
Fixed prosthodontics
Statistics
Article View: 174
PDF Download: 105
Home | Glossary | News | Aims and Scope | Sitemap
Top Top

Journal Management System. Designed by NotionWave.