George, A., Khalil, A., Hassan, H. (2015). COMPARISON BETWEEN CYLINDER AND TAPERED IMPLANTS IN DELAYED IMMEDIATE PLACEMENT. Alexandria Dental Journal, 40(2), 221-228. doi: 10.21608/adjalexu.2015.59156
A George; A Khalil; Hassan Hassan. "COMPARISON BETWEEN CYLINDER AND TAPERED IMPLANTS IN DELAYED IMMEDIATE PLACEMENT". Alexandria Dental Journal, 40, 2, 2015, 221-228. doi: 10.21608/adjalexu.2015.59156
George, A., Khalil, A., Hassan, H. (2015). 'COMPARISON BETWEEN CYLINDER AND TAPERED IMPLANTS IN DELAYED IMMEDIATE PLACEMENT', Alexandria Dental Journal, 40(2), pp. 221-228. doi: 10.21608/adjalexu.2015.59156
George, A., Khalil, A., Hassan, H. COMPARISON BETWEEN CYLINDER AND TAPERED IMPLANTS IN DELAYED IMMEDIATE PLACEMENT. Alexandria Dental Journal, 2015; 40(2): 221-228. doi: 10.21608/adjalexu.2015.59156
COMPARISON BETWEEN CYLINDER AND TAPERED IMPLANTS IN DELAYED IMMEDIATE PLACEMENT
Bachelor in Dentistry, BDS, Faculty of Dentistry, Alexandria University.
Abstract
Background: Implant geometry has a major impact on insertion torque values and primary stability, and bone engagement during implant insertion differs according to implant morphology. Objective: This study was aimed to compare the implant survival and success as outcome of 2 types of implant morphology either the tapered or cylinder form in delayed immediate placement of dental implant. Materials and methods: A total of 20 implants (10 for tapered and 10 for cylinder implants) were inserted after tooth extraction i.e. delayed immediate implant placement. The primary stability of each implant was measured by using insertion torque value. Then, implant examined clinically and radiographically for success criteria after placement. Results: The insertion torque measurement was showed 38.50 ± 4.74Ncm as a mean value for the tapered implant and 26.0 ± 5.16 Ncm for cylinder implant while the insertion time for tapered was 0.71 ± 0.07 second/mm and for cylinder was 0.95 ± 0.14 second/mm. Conclusion: Tapered implants showed better primary stability than straight-walled implants and had a higher success rate. A higher insertion torque can lead to the destruction of peri-implant bone, compromising osseointegration and failure of dental implant.
1. Huang HL, Chang CH, Hsu JT, Fallgatter AM, Ko CC. Comparison of implant body designs and threaded designs of dental implants: a 3-dimensional finite element analysis. Int J Oral Maxillofac Implants. 2007;22:551-62.
2. Morris HF, Ochi S, Crum P, Orenstein IH, Winkler SJ. AICRG, Part I: A 6-year multicentered, multidisciplinary clinical study of a new and innovative implant design. Oral Implantol. 2004;30:125-33.
3. Negri B, Calvo-Guirado JL, Maté Sánchez de Val JE, Delgado Ruiz RA, Ramírez Fernández MP, Gómez Moreno G, et al. Biomechanical and bone histomorphological evaluation of two surfaces on tapered and cylindrical root form implants: An experimental study in dogs. Clin Implant Dent Relat Res. 2013;15:799-808.
4. Lang NP, Pun L, Lau KY, Li KY, Wong MC. A systematic review on survival and success rates of implants placed immediately into fresh extraction sockets after at least 1 year. Clin Oral Implants Res. 2012;23:39-66.
5. Polizzi G, Grunder U, Goené R, Hatano N, Henry P, Jackson WJ, et al. Immediate and delayed implant placement into extraction sockets: a 5-year report. Clin Implant Dent Relat Res. 2000;2:93-9.
6. Siegele D, Soltesz U. Numerical investigations of the influence of implant shape on stress distribution in the jaw bone. Int J Oral Maxillofac Implants. 1989;4:333-40.
7. Esposito M, Hirsch JM, Lekholm U, Thomsen P. Biological factors contributing to failures of osseointegrated oral implants. (i). Success criteria and epidemiology. Eur J Oral Sci. 1998;106:527-51.
8. Chen ST, Wilson TG Jr, Hämmerle CH. Immediate or early placement of implants following tooth extraction: review of biologic basis, clinical procedures, and outcomes. Int J Oral Maxillofac Implants. 2004;19:12-25.
9. Fugazzotto PA. Success and failure rates of osseointegrated implants in function in regenerated bone for 72 to 133 months. Int J Oral Maxillofac Implants. 2005;20:77-83.
10. Hammerle CH, Chen ST, Wilson TG Jr. Consensus statements and recommended clinical procedures regarding the placement of implants in extraction sockets. Int J Oral Maxillofac Implants. 2004;19: 26- 8.
11. Polizzi G, Grunder U, Goene R. Immediate and delayed implant placement into extraction sockets: A 5-year report. Clin Implant Dent Relat Res. 2000; 22:93-9.
12. Wilson TG, Weber HP. Classification of and therapy for areas of deficient bony housing prior to dental implant placement. Int J Periodontics Restorative Dent. 1993;13:451-9.
13. Becker W, Becker BE, Handelsman M, Ochsenbein C, Albrektsson T. Guided tissue regeneration for implants placed into extraction sockets: A study in dogs. J Periodontol. 1991;62:703-9.
14. Wilson TG. Guided tissue regeneration around dental implants in immediate and recent extraction sites: Initial observations. Int J Periodontics Restorative Dent. 1992; 12:185-93.
15. Gher ME, Quintero G, Assad D, Monaco E, Richardson AC. Bone grafting and guided bone regeneration for immediate dental implants in humans. J Periodontol. 1994;65: 881-991.
16. Lim SA, Cha JY, Hwang CJ. Insertion torque of orthodontic miniscrews according to changes in shape, diameter and length. Angle Orthod. 2008;78:234-40.
17. Atsumi M, Park SH, Wang HL. Methods used to assess implant stability: current status. Int J Oral Maxillofac Implants. 2007;22:743-54.
18. Trisi P, De Benedittis S, Perfetti G, Berardi D. Primary stability, insertion torque and bone density of cylindric implant ad modum Brånemark: Is there a relationship? An invitro study. Clin Oral Implants Res. 2011;22:567-70.
19. Makary C, Rebaudi A, Mokbel N, Naaman N. Peak insertion torque correlated to histologically and clinically evaluated bone density. Implant Dent. 2011;20:182-91.
20. McClanahan SF, Bartizek RD, Biesbrock AR. Identification and consequences of distinct LöeSilness gingival index examiner styles for the clinical assessment of gingivitis. J Periodontol. 2001;72:383- 92.
22. Steflik DE, Koth DL, Robinson FG, McKinney RV, Davis BC, Morris CF, et al. Prospective investigation of the single-crystal sapphire endosteal dental implant in humans: ten-year results. J Oral Implantol. 1995;21:8-18.
23. Brouwers JEIG, Lobbezoo F, Visscher CM, Wismeijer D, Naeije M. Reliability and validity of the instrumental assessment of implant stability in dry human mandibles. J Oral Rehabil. 2009; 36: 279-83.
24. Chong L, Khocht A, Suzuki JB, Gaughan J. Effect of implant design on initial stability of tapered implants. J Oral Implantol. 2009;35:130-5.
25. Tabassum A, Meijer GJ, Wolke JGC, Jansen JA. Influence of surgical technique and surface roughness on the primary stability of an implant in artificial bone with different cortical thickness: a laboratory study. Clin Oral Implants Res. 2010;21:213-20.
26. Turkyilmaz I, Mcglumphy EA. Influence of bone density on implant stability parameters and implant success: a retrospective clinical study. BMC Oral Health. 2008; 8: 32.
27. Friberg B, Sennersby L, Meredith N, Lekholm U. A comparison between cutting torque and resonance frequency measurements of maxillary implants: A 20- month clinical study. Int J Oral Maxillofac Surg1999; 28:297–303.
28. Kahraman S, Bal BT, Asar NV, Turkyilmaz I, Tözüm TF. Clinical study on the insertion torque and wireless resonance frequency analysis in the assessment of torque capacity and stability of self-tapping dental implants.J Oral Rehabil. 2009;36:755-61.
29. Degidi M, Daprile G, Piattelli A. Determination of primary stability: a comparison of the surgeon’s perception and objective measurements. Int J Oral Maxillofac Implants. 2010;25:558-61.
30. Brouwers JE, Lobbezoo F, Visscher CM, Wismeijer D, Naeije M. Reliability and validity of the instrumental assessment of implant stability in dry human mandibles. J Oral Rehabil. 2009;36:279-83.
31. Al-Nawas B, Wagner W, Grötz KA. Insertion torque and resonance frequency analysis of dental implant systems in an animal model with loaded implants. Int J Oral Maxillofac Implants. 2006;21:726-32.
32. Javed F, Romanos GE. The role of primary stability for successful immediate loading of dental implants. A literature review. J Dent. 2010;38:612-20.
33. Degidi M, Piattelli A. 7-Year follow-up of 93 immediately loaded titanium dental implants. J Oral Implantol. 2005;310:25-31.
34. Rokn A, Ghahroudi AR, Mesgarzadeh A, Miremadi A, Yaghoobi S. Evaluation of stability changes in tapered and parallel wall implants: A human clinical trial. J Dent (Tehran). 2011;8:186-200.
35. Bilhan H, Geckili O, Mumcu E, Bozdag E, Sünbüloğlu E, Kutay O. Influence of surgical technique, implant shape and diameter on the primary stability in cancellous bone. J Oral Rehabil. 2010;37:900-7.
36. Menicucci G, Pachie E, Lorenzetti M, Migliaretti G, Carossa S. Comparison of primary stability of straight-walled and tapered implants using an insertion torque device. Int J Prosthodont. 2012;25Craniomaxillofac Surg. 2012; 40: 321-8.