Muhammed B., E., Muhammed A., G., Seham A., H. (2016). EXTENDED-STORAGE IRREVERSIBLE HYDROCOLLOID IMPRESSION MATERIALS. Alexandria Dental Journal, 41(2), 146-149. doi: 10.21608/adjalexu.2016.59269
Muhammed B., E., Muhammed A., G., Seham A., H. (2016). 'EXTENDED-STORAGE IRREVERSIBLE HYDROCOLLOID IMPRESSION MATERIALS', Alexandria Dental Journal, 41(2), pp. 146-149. doi: 10.21608/adjalexu.2016.59269
Muhammed B., E., Muhammed A., G., Seham A., H. EXTENDED-STORAGE IRREVERSIBLE HYDROCOLLOID IMPRESSION MATERIALS. Alexandria Dental Journal, 2016; 41(2): 146-149. doi: 10.21608/adjalexu.2016.59269
Instructor at the removable prosthodontics department, faculty of Dentistry, Alexandria University, Alexandria, Egypt.
Abstract
INTRODUCTION: There are many contingencies, so many dentists do not pour their own impressions immediately which clears the need for extended-storage alginate impression materials. OBJECTIVES: Evaluating and comparing three extended-storage alginate impression materials concerning their dimensional stability. MATERIALS AND METHODS: One hundred and eighty (180) specimens were prepared in accordance with ADA specification No. 18 using three extended-storage alginates; Hydrogum5 (Zhermack), Cavex ColorChange (Cavex) and Blueprint X Crème (Dentsply). Following to ADA specification No. 19 dimensional stability was evaluated directly at six intervals; 0, 24, 48, 72, 96 and 120 hours using 10 specimens/interval /material. Specimens for delayed evaluation, were stored moistened within sealed plastic bags in a dark room at 23 ±1ºc. RESULTS: All impression materials showed initial expansion and ended with a net shrinkage. Cavex ColorChange showed the least dimensional changes. Dimensional changes of Cavex ColorChange, Hydrogum5 and Blueprint Xcrème ranged (0.14 - 0.59, 0.37 - 2.07 and 0.35 - 1.40% respectively). CONCLUSION: While Cavex ColorChange can be stored up to 120 hours without clinically significant dimensional changes, Hydrogum5 and Blueprint Xcrème should be poured immediately for the best results.
1. Carr AB, McGivney GP, Brown DT. McCracken's Removable partial prosthodontics, 12th ed, St. Louis: Mosby; 2010.
2. Nallamuthu NA, Braden M, Patel MP. Some aspects of the formulation of alginate dental impression materials-Setting characteristics and mechanical properties. J Dental Materials. 2012;28:756–62.
3. Dahl LB, Dymbe B, Valderhaug J. Bonding properties and dimensional stability of hydrocolloid impression systems in fixed prosthodontics. J Prosthet Dent. 1985;53:796‑800.
4. Sedda M, Casarotto A, Rausita A, Borracchini A. Effect of storage time on the accuracy of casts made from different irreversible hydrocolloids. J Contemporary Dental Practice. 2008;9:59-66.
5. Walker MP, Burckhard J, Mitts DA, Williams KB. Dimensional change over time of extended-storage alginate impression materials. Angle Orthod. 2010;80:1110-15.
6. Rodrigues SB, Augusto CR, Leitune VCB, Samuel SMW, Collares FM. Influence of delayed pouring on irreversible hydrocolloid properties. J Brazilian Oral Research (São Paulo). 2012;26:404-9.
7. Imbery TA, Nehring J, Janus C, Moon PC. Accuracy and dimensional stability of extended-pour and conventional alginate impression materials. J Am Dent Assoc. 2010;141:32-9.
8. Mosharraf R, Nosouhian S, Salehi M. Effect of storage time on dimensional stability of Extended-pour irreversible hydrocolloid impression material. J Isfahan Dental School. 2011;7:246-55.
9. Rohanian A, Shabestari GO, Zeighami S, Samadi MJ, Shamshiri AR. Effect of Storage Time of ExtendedPour and Conventional Alginate Impressions on Dimensional Accuracy of Casts. J Dentistry (Tehran). 2014;11:655-64.
10.Revised American National Standards Institute/American Dental Association, ANSI/ADA, Specification No. 18 for dental alginate impression materials, Chicago Ill: ADA; 1992.
11. American National Standard Institute/American Dental Association, ANSI/ADA, Specification No. 19 for Dental Elastomeric Impression Materials, Chicago Ill: ADA; 2004.
12. Fernandes A, Dua N, Herekar M. Corrective Primary Impression Technique. Open Dental Journal. 2010;4:27-8.
13. Kitamura A, Kawai Y. Basic investigation of the laminated alginate impression technique: Setting time, permanent deformation, elastic deformation, consistency, and tensile bond strength tests. J Prosthodontic Research. 2015;59:49-54.
14. Eriksson A, Ockert-Eriksson G, Lockowandt P. Accuracy of irreversible hydrocolloids (alginates) for fixed prosthodontics. A comparison between irreversible hydrocolloid, reversible hydrocolloid, and addition silicone for use in the syringe-tray technique. Eur J Oral Sci. 1998;106:651-60.
15.Bayramoğlu E, Özkan YK, Yildiz C. Comparison of marginal and internal fit of presson-metal and conventional ceramic systems for three- and four-unit implant-supported partial fixed dental prostheses: An in vitro study. J Prosthet Dent. 2015;114:52-8.
16. Fellows CM, Thomas GA. Determination of bound and unbound water in dental alginate irreversible hydrocolloid by nuclear magnetic resonance spectroscopy. J Dental Materials. 2009;25:486-93.