Ahmed, M., AbdelHamid, A., AlAbbasy, F. (2019). ACCURACY OF IMPLANT PLACEMENT USING TWO DIFFERENT TYPES OF CAD/CAM SURGICAL GUIDES (AN INVITRO STUDY). Alexandria Dental Journal, 44(3), 28-33. doi: 10.21608/adjalexu.2019.63552
Moustafa F. Ahmed; Ahmed M. AbdelHamid; Fayza H. AlAbbasy. "ACCURACY OF IMPLANT PLACEMENT USING TWO DIFFERENT TYPES OF CAD/CAM SURGICAL GUIDES (AN INVITRO STUDY)". Alexandria Dental Journal, 44, 3, 2019, 28-33. doi: 10.21608/adjalexu.2019.63552
Ahmed, M., AbdelHamid, A., AlAbbasy, F. (2019). 'ACCURACY OF IMPLANT PLACEMENT USING TWO DIFFERENT TYPES OF CAD/CAM SURGICAL GUIDES (AN INVITRO STUDY)', Alexandria Dental Journal, 44(3), pp. 28-33. doi: 10.21608/adjalexu.2019.63552
Ahmed, M., AbdelHamid, A., AlAbbasy, F. ACCURACY OF IMPLANT PLACEMENT USING TWO DIFFERENT TYPES OF CAD/CAM SURGICAL GUIDES (AN INVITRO STUDY). Alexandria Dental Journal, 2019; 44(3): 28-33. doi: 10.21608/adjalexu.2019.63552
ACCURACY OF IMPLANT PLACEMENT USING TWO DIFFERENT TYPES OF CAD/CAM SURGICAL GUIDES (AN INVITRO STUDY)
1Bachelor of Dentistry, Faculty of Dentistry, Alexandria University, Egypt
2Professor of Removable Prosthodontics, Faculty of Dentistry, Alexandria University, Egypt
3Professor of Dental Biomaterials, Faculty of Dentistry, Alexandria University, Egypt
Abstract
more predictable prosthetic outcomes than non-guided implant surgery. OBJECTIVES: To compare the accuracy of implant placement using 3D printed and machine milled surgical guides. MATERIALS AND METHODS: Twelve polyurethane foam resin mandibular models were used in this study. Implant position was virtually planned using 3D planning software based on the preoperative CBCT of each model. Surgical guides were designed on the software and exported in STL format. Models were randomly divided into 2 groups (n=6 each). Group I: Surgical guides were manufactured using 3D printing. Group II: Surgical guides were manufactured using machine milling. Three implants were placed in each model using CAD/CAM surgical guides. The 3D position of the planned and placed implants, in terms of the linear deviations of the implant head and apex and the angular deviations of the implant axis, was compared by superimposing the pre- and postoperative CBCT using dedicated software. The MannWhitney U test was used for comparison (P <0.05). RESULTS: The mean coronal, apical and angular deviation for Group I were 0.72 ± 0.21 mm, 1.1 ± 0.42 mm and 2.5° ± 1.2° respectively, while for Group II they were 0.85 ± 0.3 mm, 1.3 ± 0.37 mm and 3.09° ± 0.89° degrees respectively. No significant differences were found between both groups for any of the measurements. CONCLUSIONS: 3D printing gave better results over machine milling; however, both types can be used in manufacturing surgical guides as difference in accuracy is not statistically significant. The accuracy of implants in both groups was within the safety margin of previous studies.
Widmann G, Bale RJ. Accuracy in computer-aided implant surgery--a review. Int. J. Oral Maxillofac. Implants 2006;21:305–13.
Adell R, Lekholm U, Rockler B, Brånemark PI. A 15- year study of osseointegrated implants in the treatment of the edentulous jaw. Int. J. Oral Surg. 1981;10:387– 416.
Albrektsson T, Zarb G, Worthington P, Eriksson AR. The long-term efficacy of currently used dental implants: a review and proposed criteria of success. Int. J. Oral Maxillofac. Implants 1986;1:11–25.
Adell R, Eriksson B, Lekholm U, Brånemark PI, Jemt T. Long-term follow-up study of osseointegrated implants in the treatment of totally edentulous jaws. Int. J. Oral Maxillofac. Implants 1990;5:347–59.
lbrektsson T. On long-term maintenance of the osseointegrated response. Aust. Prosthodont. J. Aust. Prosthodont. Soc. 1993;7 Suppl:15–24.
Goodacre CJ, Bernal G, Rungcharassaeng K, Kan JYK. Clinical complications with implants and implant prostheses. J. Prosthet. Dent. 2003;90:121–32.
Binon PP. Treatment planning complications and surgical miscues. J. Oral Maxillofac. Surg. Off. J. Am. Assoc. Oral Maxillofac. Surg. 2007;65:73–92.
Kopp KC, Koslow AH, Abdo OS. Predictable implant placement with a diagnostic/surgical template and advanced radiographic imaging. J. Prosthet. Dent. 2003;89:611–5.
Fortin T, Champleboux G, Lormée J, Coudert JL. Precise Dental Implant Placement in Bone Using Surgical Guides in Conjunction With Medical Imaging Techniques. J. Oral Implantol. 2000;26:300–3.
C. M. Dental Implant Prosthetics, 2e. 1 edition. St. Louis, Mo.: Mosby; 2014.
Park C, Raigrodski AJ, Rosen J, Spiekerman C, London RM. Accuracy of implant placement using precision surgical guides with varying occlusogingival heights: an in vitro study. J. Prosthet. Dent. 2009;101:372–381.
Garber DA, Belser UC. Restoration-driven implant placement with restoration-generated site development. Compend. Contin. Educ. Dent. Jamesburg NJ 1995 1995;16:796, 798–802, 804.
D’Souza KM, Aras MA. Types of Implant Surgical Guides in Dentistry: A Review. J. Oral Implantol. 2012;38:643–52.
Benavides E, Rios HF, Ganz SD, An C-H, Resnik R, Reardon GT, et al. Use of cone beam computed tomography in implant dentistry: the International Congress of Oral Implantologists consensus report. Implant Dent. 2012;21:78–86.
Belser UC, Schmid B, Higginbottom F, Buser D. Outcome analysis of implant restorations located in the anterior maxilla: a review of the recent literature. Int. J. Oral Maxillofac. Implants 2004;19 Suppl:30–42.
Farley NE, Kennedy K, McGlumphy EA, Clelland NL. Split-mouth comparison of the accuracy of computergenerated and conventional surgical guides. Int. J. Oral Maxillofac. Implants 2013;28:563–72.
Ozan O, Turkyilmaz I, Ersoy AE, McGlumphy EA, Rosenstiel SF. Clinical Accuracy of 3 Different Types of Computed Tomography-Derived Stereolithographic Surgical Guides in Implant Placement. J. Oral Maxillofac. Surg. 2009;67:394–401.
Masri R, Driscoll CF, editors. Clinical applications of digital dental technology. Ames, Iowa: John Wiley and Sons Inc; 2015.
Ventola CL. Medical applications for 3D Printing: current and projected uses. Pharm. Ther. 2014;39:704.
Horwitz J, Zuabi O, Machtei EE. Accuracy of a computerized tomography-guided template-assisted implant placement system: an in vitro study. Clin. Oral Implants Res. 2009;20:1156–62.
Tahmaseb A, Wismeijer D, Coucke W, Derksen W. Computer technology applications in surgical implant dentistry: a systematic review. Int. J. Oral Maxillofac. Implants 2014;29 Suppl:25–42.
Siessegger M, Schneider BT, Mischkowski RA, Lazar F, Krug B, Klesper B, et al. Use of an image-guided navigation system in dental implant surgery in anatomically complex operation sites. J. CranioMaxillo-fac. Surg. Off. Publ. Eur. Assoc. CranioMaxillo-fac. Surg. 2001;29:276–81.
Beuer F, Schweiger J, Edelhoff D. Digital dentistry: an overview of recent developments for CAD/CAM generated restorations. Br. Dent. J. 2008;204:505–11.
Vercruyssen M, Laleman I, Jacobs R, Quirynen M. Computer-supported implant planning and guided surgery: a narrative review. Clin. Oral Implants Res. 2015;26:69–76.
Komiyama A. Evaluation of computer-assisted virtual treatment planning and template-guided surgery in dental implant treatment. 2010;
Geng W, Liu C, Su Y, Li J, Zhou Y. Accuracy of different types of computer-aided design/computeraided manufacturing surgical guides for dental implant placement. Int. J. Clin. Exp. Med. 2015;8:8442.
Turbush SK, Turkyilmaz I. Accuracy of three different types of stereolithographic surgical guide in implant placement: an in vitro study. J. Prosthet. Dent. 2012;108:181–188.
Miyashiro M, Suedam V, Moretti Neto RT, Ferreira PM, Rubo JH. Validation of an experimental polyurethane model for biomechanical studies on implant supported prosthesis - tension tests. J. Appl. Oral Sci. 2011;19:244–8.
Lee J-H, Kim S-M, Paeng J-Y, Kim M-J. Implant surgery based on computer simulation surgical stent and the assessment with the image fusion technique. J. Korean Assoc. Oral Maxillofac. Surg. 2010;36:402–7.
Moon S-Y, Lee K-R, Kim S-G, Son M-K. Clinical problems of computer-guided implant surgery. Maxillofac. Plast. Reconstr. Surg. 2016;38:15.
Azari A, Nikzad S. The evolution of rapid prototyping in dentistry: a review. Rapid Prototyp. J. 2009;15:216– 225.
Van Assche N, Vercruyssen M, Coucke W, Teughels W, Jacobs R, Quirynen M. Accuracy of computer-aided implant placement. Clin. Oral Implants Res. 2012;23:112–23.
Giacomo GAPD, Cury PR, Araujo NS de, Sendyk WR, Sendyk CL. Clinical Application of Stereolithographic Surgical Guides for Implant Placement: Preliminary Results. J. Periodontol. 2005;76:503–7.
Vieira DM, Sotto-Maior BS, Barros CAV de S, Reis ES, Francischone CE. Clinical accuracy of flapless computer-guided surgery for implant placement in edentulous arches. Int. J. Oral Maxillofac. Implants 2013;28:1347–51.
Abduo J, Lyons K, Bennamoun M. Trends in ComputerAided Manufacturing in Prosthodontics: A Review of the Available Streams. Int. J. Dent. 2014;2014:e783948.
Valente F, Schiroli G, Sbrenna A. Accuracy of computer-aided oral implant surgery: a clinical and radiographic study. Int. J. Oral Maxillofac. Implants 2009;24:234–42.
Worthington P. Injury to the inferior alveolar nerve during implant placement: a formula for protection of the patient and clinician. Int. J. Oral Maxillofac. Implants 2004;19:731–4.