• Home
  • Browse
    • Current Issue
    • By Issue
    • By Author
    • By Subject
    • Author Index
    • Keyword Index
  • Journal Info
    • About Journal
    • Aims and Scope
    • Editorial Board
    • Publication Ethics
    • Peer Review Process
  • Guide for Authors
  • Submit Manuscript
  • Contact Us
 
  • Login
  • Register
Home Articles List Article Information
  • Save Records
  • |
  • Printable Version
  • |
  • Recommend
  • |
  • How to cite Export to
    RIS EndNote BibTeX APA MLA Harvard Vancouver
  • |
  • Share Share
    CiteULike Mendeley Facebook Google LinkedIn Twitter
Alexandria Dental Journal
arrow Articles in Press
arrow Current Issue
Journal Archive
Volume Volume 50 (2025)
Volume Volume 49 (2024)
Volume Volume 48 (2023)
Volume Volume 47 (2022)
Volume Volume 46 (2021)
Volume Volume 45 (2020)
Volume Volume 44 (2019)
Issue Issue 3
Issue Issue 2
Issue Issue 1
Volume Volume 43 (2018)
Volume Volume 42 (2017)
Volume Volume 41 (2016)
Volume Volume 40 (2015)
Ismail, H., Abbas, F., El Gindy, N. (2019). CLINICAL EVALUATION OF POLYOXYMETHYLENE PARTIAL DENTURES DESIGNED AND FABRICATED BY USING CAD/CAM TECHNOLOGY. Alexandria Dental Journal, 44(2), 77-83. doi: 10.21608/adjalexu.2019.57367
Haitham A. Ismail; Faten S. Abbas; Nazik A. El Gindy. "CLINICAL EVALUATION OF POLYOXYMETHYLENE PARTIAL DENTURES DESIGNED AND FABRICATED BY USING CAD/CAM TECHNOLOGY". Alexandria Dental Journal, 44, 2, 2019, 77-83. doi: 10.21608/adjalexu.2019.57367
Ismail, H., Abbas, F., El Gindy, N. (2019). 'CLINICAL EVALUATION OF POLYOXYMETHYLENE PARTIAL DENTURES DESIGNED AND FABRICATED BY USING CAD/CAM TECHNOLOGY', Alexandria Dental Journal, 44(2), pp. 77-83. doi: 10.21608/adjalexu.2019.57367
Ismail, H., Abbas, F., El Gindy, N. CLINICAL EVALUATION OF POLYOXYMETHYLENE PARTIAL DENTURES DESIGNED AND FABRICATED BY USING CAD/CAM TECHNOLOGY. Alexandria Dental Journal, 2019; 44(2): 77-83. doi: 10.21608/adjalexu.2019.57367

CLINICAL EVALUATION OF POLYOXYMETHYLENE PARTIAL DENTURES DESIGNED AND FABRICATED BY USING CAD/CAM TECHNOLOGY

Article 13, Volume 44, Issue 2, August 2019, Page 77-83  XML PDF (547.28 K)
DOI: 10.21608/adjalexu.2019.57367
View on SCiNiTO View on SCiNiTO
Authors
Haitham A. Ismail1; Faten S. Abbas2; Nazik A. El Gindy3
1B.D.S. Prosthodontic Department, Faculty of dentistry, Alexandria University, Alexandria, Egypt
2Professor of Prosthodontic, Faculty of dentistry, Alexandria University, Alexandria Egypt
3Professor at Industrial Pharmacy Department, Faculty of Pharmacy, Alexandria University, Alexandria Egypt
Abstract
INTRODUCTION: Recent researches had shown that, in principle, computer-assisted design, computer-assisted manufacture and rapid prototype technologies (CAD/CAM) can be successfully applied to the fabrication of removable partial denture (RPD) alloy frameworks and replace laboratory crafting techniques. The (CAD/CAM) techniques have been widely used for a long time to manufacture dental prostheses. Polyoxymethylene (POM) also known as acetal resin has been used as an alternative tooth- colored denture base and denture clasps material since 1986 and was promoted primarily for superior esthetic. OBJECTIVES: To evaluate clinically the use of Polyoxymethylene partial dentures designed and fabricated by using CAD/CAM technology compared to conventional cobalt chromium partial denture through both the masticatory efficiency and patient satisfaction. MATERIALS AND METHODS: This clinical trial was conducted on twenty mandibular partially edentulous patients (Kennedy class I) who received two types of RPD. Type I was Polyoxymethylene partial denture designed and fabricated by using CAD/CAM Technology and Type II was cobalt chromium partial denture fabricated using the conventional technique .At time of denture insertion, the masticatory efficiency of both types of dentures was evaluated for each patient .After 3 months of denture use, each patient was clinically evaluated through both the masticatory efficiency and patient satisfaction. RESULTS: Type I RPD showed better masticatory efficiency than Type II RPD but without statistical significant values at different follow up periods. Patients showed more satisfaction with type I RPD than with type II RPD with a significant value. CONCLUSIONS: Polyoxymethylene partial denture designed and fabricated by using CAD/CAM Technology is a favorable treatment for partially edentulous patients showing improvement of masticatory efficiency and favorable patient satisfaction.
Keywords
Polyoxymethylene; Cobalt Chromium; Partial Denture
Main Subjects
Prosthodontics
References
  1. Moreno de Delgado M, Garcia LT, Rudd KD. Camouflaging partial denture clasps. J Prosthet Dent. 1986;55:656-60.
  2. Ozcan M. The use of chair side silica coating for different dental applications: a clinical report. J Prosthet Dent. 2002;87:469-72.
  3. Highton R, Caputo A, Matyas J. Force transmission and retentive capabilities utilizing labial and palatal I-bar partial dentures. J Oral Rehabil. 1987;14:489-99.
  4. Pardo-Mindan S, Ruiz-Villandiego JC. A flexible lingual clasp as an aesthetic alternative: A clinical report. J Prosthet Dent. 1993;69:245-6.
  5. Chow TW, Clark RK, Clarke DA, Ho GF. A rotational path of insertion for Kennedy- Class IV removable partial dentures. Br Dent J. 1988;164:180-3.
  6. Prieskel HW. Precision Attachments in Dentistry. In: Preiskel HW, (ed). Precision Attachments in Dentistry. 3rd ed. London: Henry Kimpton Ltd; 1979.
  7. Aleksandruk G, Frączak B, Szymaniak L, Tutak M, Kubrak J. Adhesion of Candida albicansto solid acrylic surfaces and soft denture-lining. Protet Stomatol. 2003;53:44-9.
  8. Turner JW, Radford DR, Sherriff M. Flexural properties and surface finishing of acetal resin denture clasps. J Prosthet. 1999;8:188-95.
  9. Fitton JS, Davies EH, Howlett JA, Pearson GJ. The physical properties of a polyacetal denture resin. Clin Mater. 1994;17:125-9.
  10. Arda T, Arikan A. An in vitro comparison of retentive force and deformation of acetal resin and cobalt chromium clasps. J Prosthet Dent. 2005;94:267-74.
  11. Williams RJ, Bibb R, Eggbeer D, Collis J. Use of CAD/CAM technology to fabricate a removable partial denture framework. J Prosthet Dent. 2006;96:96-9.
  12. Kanazawa M, Inokoshi M, Minakuchi S, Ohbayashi N. Trial of a CAD/CAM system for fabricating complete dentures. Dent Mater J. 2011;30:93-6.
  13. Freedman M, Quinn F, O'Sullivan M. Single unit CAD/CAM restorations: a literature review. J Ir Dent Assoc. 2007;53:38-45.
  14. Van der Bilt A. Assessment of mastication with implications for oral rehabilitation. Review. J Oral Rehabil. 2011;38:754-80.
  15. Sato H, Fueki K, Sueda S, Shiozaki T, Kato M, Ohyama T. A new and simple method for evaluating masticatory function using newly developed artificial test food. J Oral Rehabil. 2003;30:68-73.
  16. Fontijn-Tekamp FA, Slagter AP, Van der Bilt A, Van’t Hof MA, Witter DJ, Kalk W, et al. Biting and chewing in overdentures, full dentures, and natural dentitions. J Dent Res. 2000;79:1519-24.
  17. Sato Y, Hamada S, Akagawa Y, Tsuga K. A method for quantifying overall satisfaction of complete denture patients. J Oral Rehabil. 2000;27:952-7.
  18. Bortun CM, Sandu L, Porojan S. Using of light-curing waxes in the removable partial denture technology. Issues. 2017;2016:2015.
  19. Miyazaki T, Hotta Y, Kunii J, Kuriyama S, Tamaki Y. A review of dental CAD/CAM: current status and future perspectives from 20 years of experience. Dent Mater J. 2009;28:44-56.
  20. Salah El Din F, El-Shabrawy SM, El-Gebaly MF. The accuracy Partial Denture Frameworks Designed and fabricated By Using CAD/ CAM Technolgy (Invitro study). Int J Sci Res. 2016;5:32- 8.
  21. Paphangkorakit J, Chaiyapanya N, Sriladlao P, PIMSUPA S. Determination of chewing efficiency using muscle work. Arch Oral Biol. 2008;53:533-7.
  22. Slagter A, Bosman F, Bilt A. Comminution of two artificial test foods by dentate and endentelous subjects. J Oral Rehabil. 1993;20:59-76.
  23. Heydecke G, Akkad AS, Wolkewitz M, Vogeler M, Türp JC, Strub JR. Patient ratings of chewing ability from a randomized crossover trial: lingualized versus first premolar/canine-guided occlusion for complete dentures. Gerodontology. 2007;24:77- 86.
  24. Esraa MA. Colorimetric comparative analysis of masticatory efficiency in complete dentures weares with two different occlusal concepts. M.Sc. Thesis. Faculty of Dentistry, Alexandria University. 2014.
  25. Celebic A, Knezovic-Zlataric D. A comparison of patient's satisfaction between complete and partial removable denture wearers. J Dent. 2003;31:445-51.
  26. Sierpińska T, Gołębiewska M. Effect of removable partial dentures on the masticatory function improvement. Protet Stomatol. 2007;57:176-82.
  27. Ducia CC, Simone MB, Eduardo DLF, Elken GR, Cassiano KR, Rosemary SAS. Functional evaluation of oral rehabilitation with removable partial dentures after five years. J Appl Oral Sci. 2006;14:111-6.
  28. Macura-Karbownik A, Chladek G, Żmudzki J, Kasperski J. Chewing efficiency and occlusal forces in PMMA, acetal and polyamide Acta Bioeng Biomech. 2016;18:137-44.
  29. Lekha K, Savitha NP, Roseline M, Nadiger RK. Acetal resin as an esthetic clasp material. J Interdiscip Dent. 2012;2:11-4.
  30. Al-Jammali ZMJ, Al Nakkash WAH. Clinical evaluations for the masticatory efficiency of heat cure resin and flexible types of denture base materials. J Bagh College Dent. 2013;25:57-61.
  31. Mustafa GM, Abed AlBaki MA, Naji SA. Comparing the Effects of Denture Base Materials on Hygiene of Mucosal Denture Bearing Area. Tikrit J Dent Sci. 2013;1:71-6.
  32. Taleb FAA, Eltorky IR, ElSheikh MM, Moula SA. Patient satisfaction and radiographyical evaluation of acetal resin retentive clasp arm versus conventional clasp on abutment teeth in upper unilateral removable partial dentures. J Am Sci. 2013;9:425-32.
  33. Kotake M, Wakabayashi N, Ai M, Yoneyama T, Hamanaka H. Fatigue resistance of titanium-nickel alloy cast clasps. Int J Prosthodont. 1997;10:547-52.
  34. Bortun C, Lakatos S, Sandu L, Negrutiv M, Ardelean L. Metal free removable partial dentures made of thermoplastic material. TMJ 2006;56:80-7.
Statistics
Article View: 416
PDF Download: 1,446
Home | Glossary | News | Aims and Scope | Sitemap
Top Top

Journal Management System. Designed by NotionWave.